Area Power Controller

Материал из Tau Ceti Station Wiki
Версия от 17:33, 13 декабря 2013; Dred1792 (обсуждение | вклад) (Новая страница: «== Airlock == '''See also: Making an Airlock, Hacking an Airlock ''' File:airlock.png Standard Air…»)
(разн.) ← Предыдущая | Текущая версия (разн.) | Следующая → (разн.)
Перейти к навигации Перейти к поиску

Airlock

See also: Making an Airlock, Hacking an Airlock

Файл:Airlock.png Standard Airlock. They come in many colors signifying different access levels and do a good job of blocking airflow as long as they're closed.

Depending on your ИД which can be changed by the Captain or Head of Personnel you can access certain doors. For example a Medical Doctor cannot access the Bridge.

APC

See also: Making an APC

Файл:APC.png The APC (Area Power Controller) controls the power output to a room. Each room generally has one APC. APCs require Engineer-level access to unlock. After being unlocked, an APC can be used to switch various electrical components of a room on and off. As an AI if your control wire to an APC is cut, you will not be able to use it. If an APC is disconnected from the external power grid (usually due to a snipped cable), its battery will rapidly drain. The AI will get a power alert from the APC when the battery reaches about 14%, which is the point when equipment and lighting in the room shut off to conserve the remaining energy.

Power: On/Off - Toggles power to the APC
Main Breaker: On/Off - Toggles power to the APC
Equipment: Auto/On/Off - Toggles power to computers, doors, and other electronic equipment.
Lighting: Auto/On/Off - Toggles power to lighting in the area.
Environmental: Auto/On/Off - Toggles power to the ventilation in the area, as well as the Air Alarm.
Overcharge Lighting Circuit: Sends a pulse throughout the lighting circuit, making any lights shatter and send out sparks.
Cover Lock: Engaged/Disengaged: Provides a cover to protect the battery.

Remember, auto power slowly cuts off each breaker when power runs low in this order:

  1. Equipment
  2. Lighting
  3. Environment

Replacing the Battery

To replace the APC battery, an Engineer (or other compatible authorities) must swipe their card on the APC.
Then, the Engineer must disengage the protective cover.
The cover can be taken off with a crowbar.
The Engineer can be free to remove the battery and insert a new one.
Once done, the Engineer can crowbar the cover back on, re-lock the cover, and lock the APC interface.

Fire Alarm

Fire alarm.png An object used to detect fires and lockdown the area. The AI is alerted whenever a fire alarm activates. They can by manually started if hit with an object or turned on using the panel. Changes colour depends on alert (Green, Blue, Red).

Atmos Alarm

Файл:Airalarm.png An object used to detect anomalies in the atmosphere and lockdown the area. The AI is alerted whenever an atmos alarm activates. If deactivated via the control panel when there is still an anomalie, the alarm will reactivate bolting any doors. Can be used to control air flow in that room.